Commodity name:
PLUTON Series Four-quadrant Power Amplifier
Product Features:
● Customized modularity
|
● 15kHz small signal bandwidth
|
● Series combination
|
● Seamless quadrant transition
|
● Parallel combination
|
● Includes a signal generator DC-5kHz
|
● Three-phase combination
|
● Extremely low distortion rate <0.5%
|
● High-speed fiber optic communication
|
● Very low output impedance
|
● With “Four Quadrants ”Working ability, can work in ‘voltage regulation’ or ‘current regulation’ mode
|
● High precision <0.2%
|
● Quick response <50µs
|
● High stability <0.1%
|
● The slew rate can reach 65V/µs
|
● Scalable I/O communication (CANbus, analog, Ethernet, switch,... )
|
● High output bandwidth DC-5kHz
|
|
Selection Instructions:
Key information
|
Power
|
0–40KW
|
Efficiency
|
95%
|
Parallel quantity
|
Up to 25
|
Concatenation quantity
|
Up to 2
|
Size
|
19”/5U
|
Control mode
|
Manual and system simulation
|
Adjustment mode
|
Voltage source, current source
|
DC output
|
AC output
|
Rated power
|
0–40KW
|
Rated power
|
0–40KW
|
Voltage range
|
0–750V
|
Voltage range
|
0–250Vrms
|
Current interval
|
0–200A
|
Current range
|
0–200Arms
|
Connection method
|
High+Low+PE
|
Connection method
|
L+N+PE
|
DC dynamic characteristics
|
Communicate dynamic characteristics
|
Voltage bandwidth
|
DC–5kHz
|
Voltage Bandwidth
|
|
Small signal bandwidth
|
15kHz
|
Small signal bandwidth
|
15kHz
|
DC offset
|
≤10mV
|
AC offset
|
≤10mV
|
Current mode rise and fall rate (10%=>90%)
|
≤50µs
|
Current mode rise and fall rate (10%=>90%)
|
≤50µs
|
Voltage mode rise and fall rate (10%=>90%)
|
≤100µs
|
Voltage mode rise and fall rate (10%=>90%)
|
≤100µs
|
Switching frequency
|
320kHz
|
Switching frequency
|
320kHz
|
DC mode accuracy
|
AC mode accuracy
|
Voltage accuracy (%FS)
|
0.2%
|
Voltage accuracy (%FS)
|
0.2%
|
Current accuracy (%FS)
|
0.2%
|
Current accuracy (%FS)
|
0.2%
|
Power accuracy (%FS)
|
0.2%
|
Power accuracy (%FS)
|
0.2%
|
Product Application: